| Measuring Transducers | ||||||
| EC-Declaration of Conformity Measuring Transducers | ||||||
| Measuring transducers supply a linear output signal which is proportional to the measured value. ZIEHL delivers measuring transducers for input signals DC 0/4-20 mA, Pt 100, thermoelement, resistance and frequency. Output signals are: DC 0/4-20 mA, 0-10 V or frequencies. Frequency signals can be easily evaluated by digital inputs of PLC's. In combination with our check switch/data scanner MUM 8 up to 8 signals can be connected to one input (i.e. display or PLC). |
||||||
| Overview (PDF) | ||||||
| for Temperature | ||||||
| Pt 100, Thermocouples | ||||||
| Type TMU | ||||||
| Type TR Limit-Relay at the same time | ||||||
| with galvanic isolation | ||||||
| Type MU1000K | ||||||
| for DC-Current / Voltage (Isolating amplifier) | ||||||
| with galvanic isolation | ||||||
| Types MU100U, MU1001K | ||||||
| with 2 inputs | ||||||
| Type TR210 | ||||||
| for AC-Current | ||||||
| Electronic-Current-Transformers | ||||||
| for Potentiometers | ||||||
| Type MU100W | ||||||
| for Resistance | ||||||
| Type TR122DA | ||||||
| Limit-Relay for analog signals | ||||||
| Type STW1000V2 | ||||||
| Measuring-Point Change-over-Switches | ||||||
| Type MUM | ||||||
| for Temperature Pt 100 | ||||||
| protect machines and systems from damage caused by asymmetry in 3-phase power-systems. Monitoring of phase sequence protects against unintentional reverse running of electric motors | ||||||
![]() |
The transducer for motor protection TMU 300 selects the hottest temperature of 3 connected sensors and transduces it into a signal 4-20 mA. It is supplied by a loop 4-20 mA and needs only 2 lines. |
|||||
| TMU300 | sealed-in electronics for temperatures up to 85°C | |||||
![]() |
TMU100V | Sensor-input 2- or 3-wire with monitoring of break, Measuring range -199...+800 °C, free selectable Easy programming of Zero and FullScale Analog output 0/4-20 mA Analog output 0-10 V Universal supply AC/DC 24-240 V Housing for DIN-rail- or wall-mount mounting height 55 mm, 70 mm wide |
||||
![]() |
TR210 | monitoring of differences in temperature 2 Sensors Pt 100 (RTD), Pt 1000 Thermocouples type B, E, J, L, N, R, S, T Inputs 0/4-20 mA und 0-10 V 2 Relays digital display scalable analog output (Measuring transducer) |
||||
![]() |
MU1000K | Universal Measuring-Transducer Pt 100 (RTD), DC-current and voltage, insulation-amplifier Potential separation between inputs and outputs Pt 100, 3-wire, -200...+800 °C Ready-configured zeros and spans Easy individual balance by pressing a button Current inputg DC 0/4 - 20 mA Voltage input DC 0/2-10 V Output sinals DC 0/4 - 20 mA, 0/2 - 10 V alle Ein-/Ausgänge in 1 Gerät Universal-Versorgungsspannung AC/DC 24-240 V |
||||
| for DC-Current / Voltage (Insulating-amplifier) | ||||||
![]() |
MU100U | Universal Insulating-amplifier Current input DC 0 - 20 mA |
||||
![]() |
MU1001K | Universal Measuring-transducer for DC-voltages Potential separation between inputs and outputs Voltage-inputs: DC 0-10 V DC 0-300 mV for current measuring with shunt (60/150/300 mV pre-set) DC 0-300 V can be compensated by the user (20/50/100/200/300 V pre-set) Zeros and Fullscales freely selectable Output signals DC 0/ -20 mA, 0-10 V 1 device for all applications Universal supply voltage AC/DC 24-240 V |
||||
| for AC-Current | ||||||
| Electronic Current-transducers | ||||||
![]() |
STWA1AH | Input AC 0...15 A, output DC 0...20 mA | ||||
| STWA2AH | Input AC 0...20/100 A, output DC 4...20 mA | |||||
| STWA1FH | Input AC 0...20 A, output frequency 0,5...20 Hz | |||||
| for Potentiometers | ||||||
![]() |
MU100W | Connection of a potentiometer 0...500 Ω bis 0...10 kΩ Zero adjustable 0...40 % FullScale adjustable 60...100 % Easy adjusting by pressing a button Analog output 0/4-20 mA, Analog output 0-10 V Universal supply AC/DC 24-240 V Housing for DIN-rail or wall-mount, 70 mm wide, mounting height 55 mm |
||||
| for Resistance | ||||||
![]() |
TR122DA | Input resistance 0...850 Ω programmable analog output 0/4-20 mA Digital display 2 limits Universal supplyl AC/DC 24-240 V |
||||
| Accessories for Measuring-transducers | ||||||
![]() |
STW1000V2 | Limit value-switch for standard signals, DC 0/4-20 mA, 0/2-10 V | ||||
| Measuring-point change-over-switch | ||||||
![]() |
MUM8 | for the link up to 8 measuring points to an evaluation unit. The inputs can be selected over 3 bits in the BCD code, e.g. with a SPS. additionally are possible an automatic operation. |
||||
![]() |
MUM16 | for the link up to 16 measuring points to an evaluation unit. The inputs can be selected over 4 bits in the BCD code, e.g. with a SPS. additionally are possible an automatic operation. |
||||