Measuring Transducers    
             
    EC-Declaration of Conformity Measuring Transducers    
           
    Measuring transducers supply a linear output signal which is proportional to the measured value.
 
ZIEHL delivers measuring transducers for input signals DC 0/4-20 mA, Pt 100, thermoelement, resistance and frequency. Output signals are: DC 0/4-20 mA, 0-10 V or frequencies. Frequency signals can be easily evaluated by digital inputs of PLC's.
In combination with our check switch/data scanner MUM 8 up to 8 signals can be connected to one input (i.e. display or PLC).
             
    Overview (PDF)  
             
    for Temperature  
      Pt 100, Thermocouples  
      Type TMU  
      Type TR Limit-Relay at the same time  
         
      with galvanic isolation  
      Type MU1000K  
             
    for DC-Current / Voltage (Isolating amplifier)  
      with galvanic isolation  
      Types MU100U, MU1001K  
             
      with 2 inputs  
      Type TR210      
             
    for AC-Current  
      Electronic-Current-Transformers  
             
    for Potentiometers  
      Type MU100W  
             
    for Resistance  
      Type TR122DA  
             
    Limit-Relay for analog signals  
      Type STW1000V2  
             
    Measuring-Point Change-over-Switches  
      Type MUM  

 

    for Temperature Pt 100  
           
    protect machines and systems from damage caused by asymmetry in 3-phase power-systems. Monitoring of phase sequence protects against unintentional reverse running of electric motors
             
      The transducer for motor protection TMU 300 selects the hottest temperature of 3 connected sensors and transduces it into a signal 4-20 mA.
It is supplied by a loop 4-20 mA and needs only 2 lines.
 
       
  TMU300 sealed-in electronics for temperatures up to 85°C  
             
             
      TMU100V Sensor-input 2- or 3-wire with monitoring of break,
Measuring range -199...+800 °C, free selectable
Easy programming of Zero and FullScale
Analog output 0/4-20 mA
Analog output 0-10 V
Universal supply AC/DC 24-240 V

Housing for DIN-rail- or wall-mount
mounting height 55 mm, 70 mm wide
 
             
             
             
             
   
for Temperature and DC-current / voltage
 
         
      TR210 monitoring of differences in temperature
2 Sensors Pt 100 (RTD), Pt 1000
Thermocouples type B, E, J, L, N, R, S, T
Inputs 0/4-20 mA und 0-10 V
2 Relays
digital display
scalable analog output (Measuring transducer)
 
             
             
      MU1000K Universal Measuring-Transducer Pt 100 (RTD), DC-current and voltage, insulation-amplifier
Potential separation between inputs and outputs

Pt 100, 3-wire, -200...+800 °C
Ready-configured zeros and spans
Easy individual balance by pressing a button
Current inputg DC 0/4 - 20 mA
Voltage input DC 0/2-10 V
Output sinals DC 0/4 - 20 mA, 0/2 - 10 V
alle Ein-/Ausgänge in 1 Gerät

Universal-Versorgungsspannung AC/DC 24-240 V
 

 

 

    for DC-Current / Voltage (Insulating-amplifier)  
           
     
      MU100U

Universal Insulating-amplifier
Potential separation between inputs and outputs

Current input DC 0 - 20 mA
Voltage input DC 0 - 10 V

Output signals DC 0/4 - 20 mA, 0 - 10 V
Offset signals 4 - 20 mA can be compensated by the user
1 device for all applications

Universal supply voltage AC/DC 24-240 V

 
             
  MU1001K Universal Measuring-transducer for DC-voltages
Potential separation between inputs and outputs

Voltage-inputs:
DC 0-10 V
DC 0-300 mV for current measuring with shunt (60/150/300 mV pre-set)
DC 0-300 V can be compensated by the user (20/50/100/200/300 V pre-set)
Zeros and Fullscales freely selectable

Output signals DC 0/ -20 mA, 0-10 V
1 device for all applications

Universal supply voltage AC/DC 24-240 V
 
         

 

 

    for AC-Current  
           
    Electronic Current-transducers
             
      STWA1AH Input AC 0...15 A, output DC 0...20 mA  
  STWA2AH Input AC 0...20/100 A, output DC 4...20 mA  
  STWA1FH Input AC 0...20 A, output frequency 0,5...20 Hz  

 

 

 

    for Potentiometers  
     
           
      MU100W Connection of a potentiometer 0...500 Ω bis 0...10 kΩ
Zero adjustable 0...40 %
FullScale adjustable 60...100 %
Easy adjusting by pressing a button
Analog output 0/4-20 mA, Analog output 0-10 V

Universal supply AC/DC 24-240 V
Housing for DIN-rail or wall-mount, 70 mm wide, mounting height 55 mm
 
       
       

 

 

 

    for Resistance  
     
           
      TR122DA Input resistance 0...850 Ω
programmable analog output 0/4-20 mA
Digital display
2 limits

Universal supplyl AC/DC 24-240 V
 
       
       

 

 

 

    Accessories for Measuring-transducers  
     
           
      STW1000V2 Limit value-switch for standard signals, DC 0/4-20 mA, 0/2-10 V  
       
       

 

 

 

    Measuring-point change-over-switch  
     
           
      MUM8 for the link up to 8 measuring points to an evaluation unit.

The inputs can be selected over 3 bits in the BCD code, e.g. with a SPS. additionally are possible an automatic operation.
 
         
  MUM16 for the link up to 16 measuring points to an evaluation unit.

The inputs can be selected over 4 bits in the BCD code, e.g. with a SPS. additionally are possible an automatic operation.